Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Ghost Voltage and Variable Frequency Drives: Why Many Measurements on Drives Are WrongMeasuring Busbars and Cable Bundles When a Rigid Clamp Jaw No Longer FitsWhen the Shock Really Happened: How a 3-Axis Data Logger Provides Evidence of Transport Damage and VibrationMeasuring Speed Without Contact: How a Stroboscope Makes Rotating Parts Appear to Stand StillWhy an Infrared Thermometer with 50:1 Optics Still Measures the Right Spot at Five Metres‘ DistanceSeamless Documentation of Dew Point and Humidity: Why a Data Logger Shows More Than Any Spot CheckWhy Your Multimeter Shows 230 Volts Even Though the Line Was Switched Off Long AgoMeasuring Temperature and Proving It at the Same Time: Why the Photo Belongs with the ReadingNon-Destructive Coating Thickness Testing: What the Paint Layer Reveals About Coating Quality and Accident DamageA 5.8 mm camera shows what lies behind the casing, without taking the machine apartVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Ghost Voltage and Variable Frequency Drives: Why Many Measurements on Drives Are WrongMeasuring Busbars and Cable Bundles When a Rigid Clamp Jaw No Longer FitsWhen the Shock Really Happened: How a 3-Axis Data Logger Provides Evidence of Transport Damage and VibrationMeasuring Speed Without Contact: How a Stroboscope Makes Rotating Parts Appear to Stand StillWhy an Infrared Thermometer with 50:1 Optics Still Measures the Right Spot at Five Metres‘ DistanceSeamless Documentation of Dew Point and Humidity: Why a Data Logger Shows More Than Any Spot CheckWhy Your Multimeter Shows 230 Volts Even Though the Line Was Switched Off Long AgoMeasuring Temperature and Proving It at the Same Time: Why the Photo Belongs with the ReadingNon-Destructive Coating Thickness Testing: What the Paint Layer Reveals About Coating Quality and Accident DamageA 5.8 mm camera shows what lies behind the casing, without taking the machine apart

Bearings and imbalance show up in vibration long before the machine fails

Published on 12 October 2026 at 20:49

The fan on the extraction system has been running a little rougher for weeks. Nobody can say since when, and on the next round someone puts a hand on the housing and says it feels normal. Three weeks later the bearing seizes, the line stops, and the replacement part costs less than the lost production. Judging by hand is too imprecise as a measurement method. Vibration, on the other hand, can be recorded numerically.

Kompakte Schwingungsmesser

What the device is

The VB450 is a portable vibration meter consisting of a display unit and an external accelerometer. The sensor sits on a 0.2 m coiled cable and is attached to the machine with a magnetic adapter. It covers frequencies from 10 Hz to 1500 Hz and can display three quantities: vibration velocity as an RMS value, acceleration as a peak value, and displacement as a peak-to-peak value. The quantity is selected with a three-position switch.

Which problems it solves

Imbalance, misalignment, loose foundations and incipient bearing wear raise the vibration level, often long before noise or temperature become noticeable. The measured value replaces gut feeling with a number that can be noted down and compared with the last measurement. When the measuring button is released, the device automatically holds the value. This makes it possible to take readings even at hard-to-reach points without having to stand next to the running machine.

When and why to measure

The most sensible approach is a fixed measurement route: always the same measuring points at the bearing locations, always in the same direction, always under comparable load. The first measurement after commissioning or a bearing replacement serves as the reference. What matters then is less the individual value than the trend. If the vibration velocity rises from round to round, it is time for a planned repair.

Three typical applications

Workshop and manufacturing: On spindle motors, compressors and hydraulic pumps, a check is carried out after maintenance work to confirm that alignment and installation are correct. An elevated value after a bearing replacement points to an installation error.

Building services and facility technology: Fans, circulation pumps and chillers are measured during the maintenance round. A fan impeller with deposits shows up clearly in the reading as imbalance.

Food production: Conveyor drives, agitators and filling pumps often run continuously. Regular measurement makes it possible to schedule the bearing replacement during a cleaning or shift break rather than during operation.

Why it pays off

An unplanned shutdown almost always costs more than the measuring device: lost production, rush orders for spare parts, overtime. Consequential damage to shafts and housings adds to this when a bearing is left running too long. With a simple measuring device and a fixed route, reactive repair becomes planned maintenance. The device is compact, switches itself off after one minute and indicates when the battery is getting low. This means it is always ready for use in the tool cart.

Anyone who has so far assessed their drives by ear and feel gets a traceable basis for maintenance decisions with the VB450.

Learn more

More news

All news