Published on 18 November 2026 at 17:12
The control cabinet is isolated, yet the multimeter still shows 80 volts at the outgoing terminal. Anyone who has worked in maintenance for long enough knows this situation. In most cases it is not real voltage but capacitively coupled ghost voltage. The result is still lost time, follow-up questions and, in the worst case, a wrong decision. Equally frustrating are measurements at the output of a variable frequency drive, where the display jumps around and no reading is usable.
What the instrument is
The EX655 clamp meter is a clamp meter with true-RMS measurement for AC and DC current. The jaw has a 30 mm opening and accommodates conductors up to 350 MCM. The backlit display shows 6000 counts with a bar graph. Two features set the instrument apart from basic clamp meters: a low-impedance LoZ input and a low-pass filter for signals from variable frequency drives.
Which problems it solves
The low-impedance input loads the measuring point enough to make capacitively coupled ghost voltages collapse. Whatever is still displayed afterwards is genuinely voltage. The low-pass filter suppresses the high-frequency components of the pulse-width-modulated output voltage, so that current and voltage downstream of the drive can be read reliably. In addition, there is a non-contact voltage detector with LED indicator, a built-in flashlight and an inrush mode that captures a motor’s starting current.
When and why to use it
Whenever a statement about the condition of an installation has to be reliable: before working on a line, when troubleshooting drives, or when checking load currents during operation. Because the instrument also handles resistance, capacitance, frequency, diode test, continuity and temperature with a type-K probe, it often replaces several instruments in the toolbox.
Three practical applications
Workshop and production: On a milling machine with a speed-controlled spindle drive, the motor current is measured downstream of the drive. With the filter active, the display stays steady, and a gradually rising current draw reveals a wearing bearing before it fails.
Building services: In a ventilation system, the inrush mode can be used to check whether the motor draws the expected current at start-up. With the capacitance measurement, the starting capacitor is checked at the same time.
Food production: Cold rooms and conveyor belts often run on long cables, where ghost voltages occur frequently. With the LoZ mode, it is quick to establish after switching off whether a line is truly de-energized. This saves discussions and unnecessary searching.
The economic aspect
The benefit lies less in the individual reading than in the false measurements that never occur in the first place. Every hour of troubleshooting caused by a phantom voltage or an unreadable drive measurement costs more in labor than a share of the purchase price. An instrument that combines current, voltage and temperature measurement also reduces walking back and forth and tool changes. Anyone who regularly works on drives and switchgear will usually recoup the investment after just a few uses.
You will find technical details and the scope of delivery on the product page.