Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Ghost Voltage and Variable Frequency Drives: Why Many Measurements on Drives Are WrongMeasuring Busbars and Cable Bundles When a Rigid Clamp Jaw No Longer FitsWhen the Shock Really Happened: How a 3-Axis Data Logger Provides Evidence of Transport Damage and VibrationMeasuring Speed Without Contact: How a Stroboscope Makes Rotating Parts Appear to Stand StillWhy an Infrared Thermometer with 50:1 Optics Still Measures the Right Spot at Five Metres‘ DistanceSeamless Documentation of Dew Point and Humidity: Why a Data Logger Shows More Than Any Spot CheckWhy Your Multimeter Shows 230 Volts Even Though the Line Was Switched Off Long AgoMeasuring Temperature and Proving It at the Same Time: Why the Photo Belongs with the ReadingNon-Destructive Coating Thickness Testing: What the Paint Layer Reveals About Coating Quality and Accident DamageA 5.8 mm camera shows what lies behind the casing, without taking the machine apartVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Ghost Voltage and Variable Frequency Drives: Why Many Measurements on Drives Are WrongMeasuring Busbars and Cable Bundles When a Rigid Clamp Jaw No Longer FitsWhen the Shock Really Happened: How a 3-Axis Data Logger Provides Evidence of Transport Damage and VibrationMeasuring Speed Without Contact: How a Stroboscope Makes Rotating Parts Appear to Stand StillWhy an Infrared Thermometer with 50:1 Optics Still Measures the Right Spot at Five Metres‘ DistanceSeamless Documentation of Dew Point and Humidity: Why a Data Logger Shows More Than Any Spot CheckWhy Your Multimeter Shows 230 Volts Even Though the Line Was Switched Off Long AgoMeasuring Temperature and Proving It at the Same Time: Why the Photo Belongs with the ReadingNon-Destructive Coating Thickness Testing: What the Paint Layer Reveals About Coating Quality and Accident DamageA 5.8 mm camera shows what lies behind the casing, without taking the machine apart

Why an Infrared Thermometer with 50:1 Optics Still Measures the Right Spot at Five Metres‘ Distance

Published on 15 November 2026 at 04:33

A bearing is running hot, a switch cabinet smells of overload, an oven seems to be outside tolerance. You point a simple infrared thermometer at it and get a reading. But what was measured may not be the component at all, but the wall behind it, or an average over a far too large area. This is exactly where the optics decide whether a measurement is usable.

Dual-laser infrared thermometer

What the device is

The 42570 dual-laser infrared thermometer is a handheld instrument for non-contact surface temperature measurement from -50 to 2200 °C. Its distance-to-spot ratio is 50:1. From a distance of five metres, it therefore captures an area approximately ten centimetres in diameter. Two laser dots help with aiming: they converge at the distance at which the measurement spot is about 25 mm. If you have to estimate the distance, this gives you a visible check.

What problems it solves

First, the question of what is actually being measured. The smaller the measurement spot relative to the distance, the less of the surroundings feeds into the reading. Second, the surface: bare metal radiates differently from painted steel or rubber. The emissivity can therefore be adjusted, and a value that is too low for shiny parts can be corrected. For cases where infrared is not enough, there is a type K thermocouple input (-50 to 1370 °C). A contact probe is included in the delivery and serves as a cross-check.

When it is used

Whenever touching is dangerous, impractical or too slow. The response time of 100 ms makes it possible to scan across a component and detect temperature trends. MAX, MIN, AVG and DIF show the highest, lowest and average values as well as the span between them. An audible alarm can be set via limit values. Via USB and software, measurement series can be transferred to a PC.

Three practical applications

Maintenance in the workshop: Motors, bearings and drives can be checked during operation from a safe distance. A bearing that runs several degrees warmer than identical units is noticed before it fails.

Electrical installations: In switch cabinets, terminal blocks and fuses, localised heating points to loose contacts or overload. With 50:1, you do not need to get close to live parts.

Heat treatment and foundry work: For furnaces, forgings or moulds, temperatures in the four-digit range are normal. Only non-contact measurement works here. The type K probe is used to check the furnace atmosphere or to verify the plausibility of the IR value.

Why it pays off

A measurement takes seconds instead of minutes, and nobody has to stop a plant just to attach a probe. Those who detect excess temperatures early plan maintenance instead of emergency repairs. In addition, wrong decisions based on an incorrectly measured value become less frequent: parts replaced unnecessarily or batches rejected wrongly. A device that takes distance, measurement area and surface into account quickly saves more than it costs.