Published on August 26, 2026 at 08:51
Two workplaces, both with an air temperature of 28 degrees and 55 percent humidity. One is in the shade, the other in the blazing sun — or next to a furnace. For a person, these are two completely different days. For an ordinary thermometer, they are the same numbers.
This is not a measurement error, but by design: a thermometer’s sensor is deliberately shielded so that radiation does not distort the reading. The very radiation that stresses the human body is therefore intentionally kept out of the measurement.
What It’s About
A WBGT meter for assessing heat stress.
- Captures the combined effect of temperature, humidity, air movement and radiant heat
- Black globe temperature (TG) for measuring direct solar and radiant heat
- In/Out function: WBGT value with or without direct sunlight
The Black Globe Is the Really Clever Part
It is a physical model of a person standing in that spot. A matte black sphere with a sensor at its center absorbs radiation just as a body does, simultaneously loses heat to the air flowing past it, and settles at an equilibrium temperature.
This single reading therefore contains three influences at once: how much radiation arrives, how warm the air is, and how strongly it is moving. A gust of wind cools the globe, just as it cools a person. Stand in front of a furnace and the reading rises, even though the air temperature stays the same.
And the wet-bulb thermometer supplies the fourth variable. It shows how well evaporation is still working — in other words, whether the body can use its only effective means of cooling at all. WBGT weights these readings into a single number instead of considering them individually.
Why There Are Two Operating Modes
Outdoors in direct sun, radiation contributes a substantial share; indoors or in the shade, hardly any. That is why the WBGT value is weighted differently in each case — and a device that knows only one formula would be systematically wrong in the other situation.
The In/Out switch ensures that the same sensor head delivers the correct index for both cases. That is the difference between a value that can be compared against a specification and a number that only points roughly in the right direction.
How It Differs from the Perceived Heat Index
A heat index based on temperature and humidity answers the question of how warm the air feels. In an office, a kitchen or a hall without strong radiant sources, that is entirely sufficient.
WBGT answers the other question: how great is the total heat load on the person, including what the sun, furnace or hot walls contribute. As soon as a radiant source is involved, the two numbers are no longer interchangeable — and WBGT is then the one on which work and rest rules are based.
Three Typical Applications
- Construction and outdoor work: Assessment in sunshine, where air temperature alone is misleading.
- Foundry, forge, bakery: Workplaces with strong radiant heat from equipment.
- Sports and training: Planning exertion on hot days.
Why It Pays Off
Heat stress costs you long before anyone drops out: concentration declines, work pace slows, error rates rise — and all of this is rarely booked as a heat problem, but as a bad day.
The practical value of a measurement is that the decision about breaks no longer depends on who demands them. A number everyone accepts turns a discussion into a rule — and that protects both sides, the employee and the person responsible.