Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Ghost Voltage and Variable Frequency Drives: Why Many Measurements on Drives Are WrongMeasuring Busbars and Cable Bundles When a Rigid Clamp Jaw No Longer FitsWhen the Shock Really Happened: How a 3-Axis Data Logger Provides Evidence of Transport Damage and VibrationMeasuring Speed Without Contact: How a Stroboscope Makes Rotating Parts Appear to Stand StillWhy an Infrared Thermometer with 50:1 Optics Still Measures the Right Spot at Five Metres‘ DistanceSeamless Documentation of Dew Point and Humidity: Why a Data Logger Shows More Than Any Spot CheckWhy Your Multimeter Shows 230 Volts Even Though the Line Was Switched Off Long AgoMeasuring Temperature and Proving It at the Same Time: Why the Photo Belongs with the ReadingNon-Destructive Coating Thickness Testing: What the Paint Layer Reveals About Coating Quality and Accident DamageA 5.8 mm camera shows what lies behind the casing, without taking the machine apartVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Ghost Voltage and Variable Frequency Drives: Why Many Measurements on Drives Are WrongMeasuring Busbars and Cable Bundles When a Rigid Clamp Jaw No Longer FitsWhen the Shock Really Happened: How a 3-Axis Data Logger Provides Evidence of Transport Damage and VibrationMeasuring Speed Without Contact: How a Stroboscope Makes Rotating Parts Appear to Stand StillWhy an Infrared Thermometer with 50:1 Optics Still Measures the Right Spot at Five Metres‘ DistanceSeamless Documentation of Dew Point and Humidity: Why a Data Logger Shows More Than Any Spot CheckWhy Your Multimeter Shows 230 Volts Even Though the Line Was Switched Off Long AgoMeasuring Temperature and Proving It at the Same Time: Why the Photo Belongs with the ReadingNon-Destructive Coating Thickness Testing: What the Paint Layer Reveals About Coating Quality and Accident DamageA 5.8 mm camera shows what lies behind the casing, without taking the machine apart

A lux meter doesn’t measure light, but light as the human eye sees it, and that is where the problem with LEDs lies

Published on August 24, 2026 at 01:06 AM

Two measuring instruments, the same luminaire, two clearly different lux readings. Both devices are working properly, and both are calibrated. The difference is that a lux meter doesn’t actually measure light, but rather light as the human eye weights it — and with colored and narrow-band LEDs, this weighting is the decisive source of error.

Color LED Light Meter LT45 with separate light sensor and coiled cable

What It’s About

A light meter designed specifically for LED lighting.

  • Measurement of white, red, yellow, green, blue and violet LED lighting as well as standard light
  • Display in lux or footcandles
  • Cosine-corrected and color-corrected measurement
  • 4000-digit LCD, min/max and average
  • Manual storage and recall of up to 99 readings
  • Separate light sensor with protective cap and coiled cable, extendable up to 1.5 m
  • Complete with battery and hard carrying case

The Problem Behind It

Lux is a physiological unit, not a purely physical one. One watt of green light appears many times brighter to the eye than one watt of red or blue light. For a meter to display lux, its sensor must therefore follow exactly this sensitivity curve of the eye. This is achieved by a filter in front of the photodiode — and how well that filter matches the curve determines the measurement accuracy.

With incandescent light, an imperfect match is hardly noticeable; with LEDs, it certainly is. An incandescent lamp radiates across the entire visible spectrum, so deviations in the filter largely average out. A colored LED, by contrast, radiates in a narrow band. If the filter is off precisely there, the error affects the result undamped — and, depending on the LED color, in different directions. This is exactly why this device offers a selection by LED color instead of a single calibration for everything.

Cosine correction is the second, often overlooked point. Illuminance refers to a surface, and light that arrives at an angle is spread over a larger area — so it contributes less, exactly in proportion to the cosine of the angle of incidence. A flat, uncorrected sensor overweights light arriving from the side. In a room with several luminaires, where most of the light does not come vertically from above, this is not a minor detail but shifts the entire result.

The remote sensor on the coiled cable finally solves a purely practical problem: the person taking the measurement is standing in the light. Anyone holding the device in their hand and looking at it shades the measuring surface with their own body. With 1.5 m of cable, the sensor can be placed exactly where the value applies — on the work surface, on the shelf, at the monitor workstation — while you step aside.

Three Typical Applications

  • Workplace lighting: Verification of illuminance at workstations, workbenches and in inspection areas.
  • LED retrofits: Before-and-after comparison when conventional luminaires are replaced with LEDs and wattage no longer tells you anything.
  • Retail, horticulture and stage: colored LED lighting, where a standard lux meter is systematically off.

Why It Pays Off

Lighting is almost always evaluated wrongly in two steps: planned by wattage, approved by eye. Both worked passably as long as all light sources radiated similarly. With LEDs, wattage is no longer a measure of brightness, and the eye adapts within minutes to a level that is too dark, without anyone noticing.

A measurement that delivers the actual value at the point where the work is done turns this into a verifiable number — both toward a client and toward a specification. And it prevents the more expensive of the two mistakes: a fully installed system that is only recognized as too dark after acceptance.