Hoppa till innehåll
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Ghost Voltage and Variable Frequency Drives: Why Many Measurements on Drives Are WrongMeasuring Busbars and Cable Bundles When a Rigid Clamp Jaw No Longer FitsWhen the Shock Really Happened: How a 3-Axis Data Logger Provides Evidence of Transport Damage and VibrationMeasuring Speed Without Contact: How a Stroboscope Makes Rotating Parts Appear to Stand StillWhy an Infrared Thermometer with 50:1 Optics Still Measures the Right Spot at Five Metres‘ DistanceSeamless Documentation of Dew Point and Humidity: Why a Data Logger Shows More Than Any Spot CheckWhy Your Multimeter Shows 230 Volts Even Though the Line Was Switched Off Long AgoMeasuring Temperature and Proving It at the Same Time: Why the Photo Belongs with the ReadingNon-Destructive Coating Thickness Testing: What the Paint Layer Reveals About Coating Quality and Accident DamageA 5.8 mm camera shows what lies behind the casing, without taking the machine apartVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Ghost Voltage and Variable Frequency Drives: Why Many Measurements on Drives Are WrongMeasuring Busbars and Cable Bundles When a Rigid Clamp Jaw No Longer FitsWhen the Shock Really Happened: How a 3-Axis Data Logger Provides Evidence of Transport Damage and VibrationMeasuring Speed Without Contact: How a Stroboscope Makes Rotating Parts Appear to Stand StillWhy an Infrared Thermometer with 50:1 Optics Still Measures the Right Spot at Five Metres‘ DistanceSeamless Documentation of Dew Point and Humidity: Why a Data Logger Shows More Than Any Spot CheckWhy Your Multimeter Shows 230 Volts Even Though the Line Was Switched Off Long AgoMeasuring Temperature and Proving It at the Same Time: Why the Photo Belongs with the ReadingNon-Destructive Coating Thickness Testing: What the Paint Layer Reveals About Coating Quality and Accident DamageA 5.8 mm camera shows what lies behind the casing, without taking the machine apart

Extech CG204 Coating Thickness Gauge with Magnetic Induction + Eddy Current: When a Zinc Protective Coating on Steel Below 80 µm Can Void the Corrosion Guarantee per ISO 9227

Published on July 8, 2026 at 3:23 PM

Coating thickness is one of the most important yet least visible quality parameters in metalworking. If the zinc layer on a steel structure is too thin, the component rusts within a few years; if the paint layer on a car body is too thick, the paint cracks under temperature cycling; if the chrome layer on chrome-plated parts is uneven, visual defects appear. These layers must be measured non-destructively and quickly — from the test bench in production to field use during incoming goods inspection. Electromagnetic sensor technology delivers exactly that, with automatic detection of the substrate type.

What the Extech CG204 Is

The Coating Thickness Gauge Tester (CG204) from Extech is a portable dual-sensor instrument for non-destructive measurement of non-metallic coatings on metallic substrates. The instrument:

  • Uses magnetic induction for ferromagnetic substrates (steel, iron).
  • Uses the eddy current method for non-ferromagnetic substrates (aluminum, copper, brass, zinc).
  • Automatically detects the substrate and selects the correct measurement method.
  • Offers two measurement modes: Single (individual measurement) and Continuous (continuous measurement).
  • Offers two operating modes: Direct (individual readings) and Group (statistics collection).
  • Stores 400 readings: 80 direct + 320 group-collected.
  • Programmable high/low alarms.
  • Calculates min/max/average automatically.
  • One- or two-point calibration.
  • USB connection with software for PC data export.
  • Complete with AAA batteries, USB cable, software, calibration standards (steel + aluminum), precision foils, and carrying case.

Basic specifications:

  • Measuring principle: Dual — magnetic induction + eddy current
  • Automatic substrate detection: Yes
  • Measuring range: 0-1250 µm (typical)
  • Resolution: 0.1 µm (at 0-100 µm), 1 µm (>100 µm)
  • Accuracy: ±(2 % + 2 µm)
  • Calibration: One- or two-point
  • Memory: 400 values (80 direct + 320 group)
  • Alarm functions: Programmable high/low thresholds
  • PC interface: USB with software
  • Power supply: 2× AAA batteries

Extech CG204 coating thickness gauge with dual sensor

Magnetic Induction Principle for Steel Substrates

Magnetic induction exploits the ferromagnetic property of steel:

  1. The sensor head contains a coil carrying alternating current at 20-40 kHz.
  2. The coil generates an alternating magnetic field.
  3. When the sensor is placed on a coated steel surface, the field penetrates the (non-magnetic) coating and reaches the steel.
  4. The steel concentrates the field (high permeability).
  5. The field strength returning to the coil is measured.
  6. The thicker the coating, the weaker the feedback — proportional to the inverse of the thickness.

Calibration: On a bare steel standard and a 500 µm foil, the instrument establishes the calibration curve. It then displays the coating thickness directly on every test piece.

Typical applications: paint on steel, zinc galvanizing, powder coating, cathodic dip coating (KTL), chrome on steel.

Eddy Current Principle for Non-Ferrous Substrates

For non-ferromagnetic (non-ferrous) metals (aluminum, copper, brass), magnetic induction does not work — these metals do not concentrate the field. Instead, the eddy current method is used:

  1. The sensor coil generates a high-frequency alternating field (1-2 MHz).
  2. The field induces eddy currents in the conductive metal surface.
  3. The eddy currents generate a opposing field that counteracts the original excitation.
  4. The change in impedance of the sensor coil is proportional to the distance between the coil and the metal.
  5. The distance corresponds to the coating thickness.

Calibration: On a bare aluminum standard and a defined foil.

Typical applications: anodizing on aluminum, chromate coating on aluminum, zinc chromate on copper, paint on aluminum car bodies.

Automatic Substrate Detection

The CG204 has both sensors integrated. With every measurement:

  1. A short test pulse (~10 ms) is sent through both sensor channels.
  2. If magnetic induction returns a strong signal → steel substrate detected.
  3. If eddy current returns a strong signal → non-ferrous substrate detected.
  4. The instrument activates the corresponding sensor calibration.
  5. The substrate type and coating thickness are shown on the display.

Practical significance: the user does not need to know whether they are measuring on steel or aluminum — the instrument decides on its own. This is especially important for mixed-material components (e.g., car bodies with both steel and aluminum elements), where manual switching would be error-prone.

Regulation-Relevant Coating Thicknesses

Standard coating thickness requirements according to ISO 1461 and industry-specific standards:

  • Hot-dip galvanizing on steel structures: At least 55 µm for structures in category C1-C3, 85 µm for C4, 100 µm for C5.
  • Automotive primer + paint: 100-160 µm total, of which KTL 15-30 µm, primer 30-50 µm, basecoat 30-50 µm, clearcoat 40-60 µm.
  • Zinc chromate on aluminum (aviation): 1-4 µm according to AMS-C-5541.
  • Anodizing on aluminum (hard anodizing): 25-100 µm according to MIL-A-8625.
  • Chrome plating on bathroom fixtures: 8-12 µm.
  • Powder coating on metal furniture: 60-120 µm.
  • Epoxy floor coating: 200-500 µm.

A CG204 gauge enables QC verification of all of these standards directly on the component.

One- vs. Two-Point Calibration

One-point calibration: The bare substrate is measured as the „zero point“; the instrument assumes a linear relationship with the coating thickness.

Two-point calibration: In addition, a known foil (typically 100-500 µm) is used, which defines the gain factor of the curve.

For precision measurements (aviation, automotive use), two-point calibration is standard. For general workshop applications, one-point is sufficient.

Where Coating Thickness Measurement Makes a Real Difference

Hot-dip galvanizing shops: QC after bath galvanizing, ensuring that ISO 1461 minimum thicknesses are met.

Automotive production: Paint QC, primer, KTL layer. Compliance with manufacturer specifications.

Aerospace and defense industry: Coatings on alloys with MIL/AMS specifications.

Electronics manufacturing: Solder mask, EMC coatings on housings.

Component coating (furniture, white goods): Powder coating QC.

Corrosion protection verification: Regular inspection of structures (bridges, ships, pipelines).

Marine applications: Anti-fouling coatings on ship hulls.

Restoration work: Old components with historical coatings, determining their condition.

Anodizing shops: Aluminum anodizing with defined thickness.

Electroplating: Chrome plating, nickel plating, and galvanizing on small components.

Accuracy and Influencing Factors

The typical accuracy of ±(2 % + 2 µm) depends on several factors:

  • Substrate roughness: A very rough surface (Ra > 5 µm) reduces accuracy.
  • Substrate curvature: On highly curved components (radius < 20 mm), the instrument must be specially calibrated.
  • Substrate thickness: With a very thin substrate (< 0.5 mm), the reverse side can have an influence.
  • Temperature: Ideally 15-25 °C. Extreme conditions require calibration at the actual temperature.
  • Substrate contamination: Oil, grease, and dust on the substrate or coating distort the measurement.

Practical Handling

  1. Place the sensor on the selected measuring point — perpendicular to the surface.
  2. Apply light contact pressure (approx. 200-500 g).
  3. The reading is displayed within 1-2 seconds.
  4. For statistical significance, take at least 5 measurements per test point (statistical process control).
  5. Values are saved to memory for later evaluation.
  6. Before each series: zero-point calibration on a bare substrate reference.

What You Get for Your Money

Extech CG204 coating thickness gauge, dual sensor with magnetic induction (steel substrates) and eddy current (non-ferrous substrates), automatic substrate detection, measuring range 0-1250 µm, resolution 0.1 µm, accuracy ±(2 % + 2 µm), Single and Continuous measurement modes, Direct and Group operating modes, 400-value memory (80 direct + 320 group), programmable high/low alarms, min/max/average statistics, one- or two-point calibration, USB PC connection with software, 2× AAA batteries, calibration standards (steel + aluminum), precision foils, carrying case.

390 EUR is the instrument investment. Compared with destructive testing by micrometric grinding (~50-100 EUR in losses per test piece plus damage to the component), non-destructive measurement pays for itself after 3-5 inspections. Compared with precision laboratory instruments (2,000-8,000 EUR), the CG204 is a portable field solution with comparable accuracy for standard applications.

Learn more: Extech CG204 Coating Thickness Gauge in the Shop →