Hoppa till innehåll
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Ghost Voltage and Variable Frequency Drives: Why Many Measurements on Drives Are WrongMeasuring Busbars and Cable Bundles When a Rigid Clamp Jaw No Longer FitsWhen the Shock Really Happened: How a 3-Axis Data Logger Provides Evidence of Transport Damage and VibrationMeasuring Speed Without Contact: How a Stroboscope Makes Rotating Parts Appear to Stand StillWhy an Infrared Thermometer with 50:1 Optics Still Measures the Right Spot at Five Metres‘ DistanceSeamless Documentation of Dew Point and Humidity: Why a Data Logger Shows More Than Any Spot CheckWhy Your Multimeter Shows 230 Volts Even Though the Line Was Switched Off Long AgoMeasuring Temperature and Proving It at the Same Time: Why the Photo Belongs with the ReadingNon-Destructive Coating Thickness Testing: What the Paint Layer Reveals About Coating Quality and Accident DamageA 5.8 mm camera shows what lies behind the casing, without taking the machine apartVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Ghost Voltage and Variable Frequency Drives: Why Many Measurements on Drives Are WrongMeasuring Busbars and Cable Bundles When a Rigid Clamp Jaw No Longer FitsWhen the Shock Really Happened: How a 3-Axis Data Logger Provides Evidence of Transport Damage and VibrationMeasuring Speed Without Contact: How a Stroboscope Makes Rotating Parts Appear to Stand StillWhy an Infrared Thermometer with 50:1 Optics Still Measures the Right Spot at Five Metres‘ DistanceSeamless Documentation of Dew Point and Humidity: Why a Data Logger Shows More Than Any Spot CheckWhy Your Multimeter Shows 230 Volts Even Though the Line Was Switched Off Long AgoMeasuring Temperature and Proving It at the Same Time: Why the Photo Belongs with the ReadingNon-Destructive Coating Thickness Testing: What the Paint Layer Reveals About Coating Quality and Accident DamageA 5.8 mm camera shows what lies behind the casing, without taking the machine apart

Why an Infrared Thermometer with 50:1 Optics Only Measures Reliably at a Distance

Published on October 15, 2026 at 03:48

A bearing is running hot, but nobody knows exactly how hot. The housing can only be seen through a gap behind a protective cover, and getting closer is not an option. With a basic infrared thermometer, you end up measuring from two meters away and capture not only the bearing but also the wall, the bracket and the ambient air. The reading is then wrong, and you often only notice once the damage is done.

Dual Laser Infrarot-Thermometer mit beschränkter NIST, 53-42570

What the device is

The Dual Laser Infrared Thermometer 53-42570 is a handheld instrument for non-contact surface measurement from -50 to 2200 °C. Its optics have a ratio of 50:1. From a distance of 50 cm, it therefore captures a spot of about 1 cm, and from 5 m, about 10 cm. Two laser points indicate the ideal measuring distance: they converge at a spot size of about one inch. The device also has a Type K input up to 1370 °C for contact measurements with a probe.

What problems it solves

Measurement uncertainty in infrared measurement mostly comes from two sources: a spot size that is too large and an incorrect emissivity. The 50:1 optics and the laser aiming aid address the first issue. The adjustable emissivity helps with the second, because matt paint, bare steel and plastic radiate very differently. With a response time of 100 ms, you can also track moving hotspots. MAX, MIN, AVG and DIF show the peak value, lowest value, average and spread, so you don’t have to write anything down as you go.

When and why to use it

Whenever touching is dangerous, impractical or too slow: with rotating parts, live equipment, hot processes or high-mounted components. Adjustable limits with an audible alarm report deviations while you keep working. Via USB, measurement series can be transferred to a PC with the supplied software and documented.

Three practical applications

Workshop and industry: In heat treatment, foundries or furnace construction, surfaces can be checked at high temperatures without having to enter the radiation zone. With bearings, gearboxes and motors, you can detect heating before it leads to failure.

Electrical: In control cabinets and at distribution boards, terminals, busbars and fuses often reveal loose connections first through heat. From a safe distance, the measurement provides a comparison between phases, and the DIF function makes the difference immediately visible.

Food production: Conveyor belts, cooling lines, ovens and packaging systems can be checked without contact, without contaminating the product or the surface. With shiny stainless steel, you should deliberately adjust the emissivity or cross-check with a probe.

Why it pays off

An unplanned shutdown usually costs more than the measuring instrument. A device that shows deviations early and reproducibly shortens troubleshooting, saves inspection rounds that require shutdowns and delivers reliable data for maintenance records. A single device for infrared and contact measurement also replaces two separate instruments.

If you need to record temperatures at a distance with traceable accuracy, you will find a tool here that stays in service for years.