Hoppa till innehåll
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Ghost Voltage and Variable Frequency Drives: Why Many Measurements on Drives Are WrongMeasuring Busbars and Cable Bundles When a Rigid Clamp Jaw No Longer FitsWhen the Shock Really Happened: How a 3-Axis Data Logger Provides Evidence of Transport Damage and VibrationMeasuring Speed Without Contact: How a Stroboscope Makes Rotating Parts Appear to Stand StillWhy an Infrared Thermometer with 50:1 Optics Still Measures the Right Spot at Five Metres‘ DistanceSeamless Documentation of Dew Point and Humidity: Why a Data Logger Shows More Than Any Spot CheckWhy Your Multimeter Shows 230 Volts Even Though the Line Was Switched Off Long AgoMeasuring Temperature and Proving It at the Same Time: Why the Photo Belongs with the ReadingNon-Destructive Coating Thickness Testing: What the Paint Layer Reveals About Coating Quality and Accident DamageA 5.8 mm camera shows what lies behind the casing, without taking the machine apartVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Ghost Voltage and Variable Frequency Drives: Why Many Measurements on Drives Are WrongMeasuring Busbars and Cable Bundles When a Rigid Clamp Jaw No Longer FitsWhen the Shock Really Happened: How a 3-Axis Data Logger Provides Evidence of Transport Damage and VibrationMeasuring Speed Without Contact: How a Stroboscope Makes Rotating Parts Appear to Stand StillWhy an Infrared Thermometer with 50:1 Optics Still Measures the Right Spot at Five Metres‘ DistanceSeamless Documentation of Dew Point and Humidity: Why a Data Logger Shows More Than Any Spot CheckWhy Your Multimeter Shows 230 Volts Even Though the Line Was Switched Off Long AgoMeasuring Temperature and Proving It at the Same Time: Why the Photo Belongs with the ReadingNon-Destructive Coating Thickness Testing: What the Paint Layer Reveals About Coating Quality and Accident DamageA 5.8 mm camera shows what lies behind the casing, without taking the machine apart

Extech SL400 Personal Noise Dosimeter with Belt Clip and Clip-On Microphone: Why a Stationary Sound Level Meter Can’t Measure the Actual Ear Exposure of a Mobile Worker

Published on July 16, 2026 at 6:45 AM

Occupational noise assessment is one of the more complicated requirements in modern HSE (Health, Safety, Environment) regulations. The fundamental parameter is LEX,8h, the daily average sound exposure over an 8-hour work shift, A-weighted to reflect human hearing.

Limit values (EU 2003/10/EC + national regulations):

  • LEX,8h ≥ 80 dB(A): Lower action value. Hearing protection must be AVAILABLE.
  • LEX,8h ≥ 85 dB(A): Upper action value. Hearing protection must be WORN.
  • LEX,8h ≥ 87 dB(A) (with hearing protection): Limit value. No exceedance permitted.

There are two fundamentally different approaches to MEASURING these values: STATIONARY measurement and PERSONAL measurement.

Stationary vs. Personal: The Critical Difference

Stationary sound level meter (SL510 as an example):

  • Is placed at a FIXED location in the room.
  • Measures only the noise at THAT point.
  • Does not follow the worker’s movements.
  • If the worker moves through areas with different noise levels, the stationary measurement misses the individual ear exposure.

Personal dosimeter (SL400):

  • Is worn by the WORKER (belt clip + shoulder microphone).
  • Moves WITH the worker.
  • Measures the actual cumulative ear exposure over the entire shift.
  • Yields LEX,8h directly from the measured data.

Practical Example: Why Personal Measurement Gives Different Results

A factory worker has the following typical 8-hour shift:

Time Activity / Location Noise level
08:00-09:30 (1.5 h) Standard production area (Machines A) 82 dB
09:30-10:00 (0.5 h) Compressor room (maintenance check) 92 dB
10:00-12:00 (2 h) Standard production 82 dB
12:00-13:00 (1 h) Canteen (lunch break) 65 dB
13:00-15:30 (2.5 h) Welding area (regular welding) 95 dB
15:30-16:00 (0.5 h) Office area (paperwork) 60 dB

Stationary meter in the standard production area: Consistently shows 82 dB. The direct „measurement“ gives LEX,8h ≈ 82 dB. BELOW 85 dB, so hearing protection is not mandatory.

Personal dosimeter: Integrates the actual exposure across all activities:

LEX,8h = 10·log₁₀ [(1/8) · Σ tᵢ · 10^(Lᵢ/10)]

Calculation: 1.5·10^8.2 + 0.5·10^9.2 + 2·10^8.2 + 1·10^6.5 + 2.5·10^9.5 + 0.5·10^6 = 2.38×10⁹ + 7.94×10⁸ + 3.17×10⁹ + 3.16×10⁶ + 7.91×10⁹ + 5×10⁵ = approx. 1.4×10¹⁰

Divided by 8: 1.75×10⁹ = 10^9.24. LEX,8h = 92.4 dB.

92.4 dB is FAR ABOVE the 85 dB limit, so hearing protection is MANDATORY. The stationary measurement MISSED the 30 minutes in the compressor room and the 2.5 hours in the welding area.

Consequence: under a stationary assessment, the worker would be UNPROTECTED. A personal dosimeter assessment identifies the actual hazard.

Physical Design of the SL400

Main unit: Compact electronics box with LCD display and control buttons. It is attached to the belt or placed in a breast pocket (typ. 100×60×25 mm, 150 g).

Clip-on microphone: 0.5″ (12.7 mm) electret condenser microphone with clip. It is attached to the shoulder or collar, 5-10 cm from the right EAR. This is the STANDARD position for personal noise dosimetry (ISO 9612).

Microphone cable: 32″ (~80 cm) shielded cable between the main unit (at the belt) and the microphone (at the shoulder).

Windscreen: Foam ball over the microphone. Prevents turbulence artifacts caused by wind or rapid head movements.

Measurement Functions and Standards

The SL400 complies with OSHA, DOD, ACGIH, IEC 61252 and ISO 9612 standards. Measured parameters:

  • Current sound level: Real-time A-weighted dB value.
  • Leq (equivalent continuous level): Time-weighted average since the start of measurement.
  • LEX,8h: Normalized to an 8-hour shift.
  • Peak level: Highest instantaneous value (C-weighted for impulse noise).
  • SEL (Sound Exposure Level): Cumulative energy exposure, normalized to 1 second.
  • TWA (Time-Weighted Average): American OSHA standard notation for LEX,8h.
  • Dose %: Percentage of the maximum permitted daily dose (100% = OSHA limit reached).

All parameters are measured and stored SIMULTANEOUSLY.

Data Logging and Storage

The SL400 stores up to 999,999 measurement values, enough for over 40 hours at a 1-second interval, or weeks at longer intervals.

Sampling interval: 1 second to 24 hours (configurable).

For a standard 8-hour shift with 1-second sampling: 28,800 measurement values per shift. The SL400 can store 30+ shifts.

Setting the Criterion Level

Different countries and standards use different limit values. The SL400 has configurable parameters:

  • Criterion level: Default 85 dB (EU), 90 dB (US OSHA).
  • Exchange rate: How much the LEX,8h increases when the exposure time doubles. Default 3 dB (EU, IEC), but OSHA allows 5 dB.
  • Peak threshold: Default 137 dB(C) for impulse noise.
  • Slow/Fast time weighting: Default SLOW (1-second integration).

For EU compliance: 85 dB / 3 dB / 137 dB / SLOW.

Calibration (94 dB / 114 dB Calibrator)

Dosimeters must be calibrated BEFORE and AFTER each measurement, per ANSI/ISO standards.

  1. Before the start of the shift: The 94 dB calibrator is slipped over the microphone. The SL400 reads the value. If it is not 94 dB, it is adjusted.
  2. After the end of the shift: Calibrate again. If the drift exceeds 1 dB (typically caused by high temperature, humidity or battery degradation), the shift data must be interpreted with caution.

The 94 dB calibrator must be purchased separately (approx. 5,000-7,000 kr for an ANSI-certified calibrator such as the Extech 407766, which was covered in an earlier HSE article).

USB Interface and PC Software

After the shift, the SL400 is connected to a PC via USB. The Windows software shows:

  • Time-history chart of the sound level.
  • Statistical analysis (Leq, Lmax, Lmin, percentiles L1, L10, L50, L90, L99).
  • Automatic LEX,8h calculation.
  • Dose % display (visualizes whether the worker has reached the limit value).
  • Peak events with timestamps.
  • Report generation for HSE documentation.
  • Export to CSV or Excel.

Applications

Industrial factories: Standard application. Every worker in noisy areas receives a dosimeter for 1-2 days per year for compliance verification.

Construction sites: Construction workers in variable noise environments (jackhammers, concrete machines, circular saws).

Mining: Underground miners in high-noise environments (drilling machines, ventilation, conveyors).

Aviation: Airport ground staff (apron workers in jet engine environments).

Military: Soldiers in armored vehicles, artillery operators, pilots.

Music industry: Live musicians, roadies, sound engineers in concert environments.

Motorsport: Motorsport mechanics in pit boxes.

Agriculture: Tractor operators, grain dryer operators.

Emergency services: Firefighters, rescue helicopter crews.

Transport operators: Bus, train and truck drivers (engine noise in the cab).

ISO 9612 Standard Methodology

ISO 9612:2009 („Determination of occupational noise exposure — Engineering method“) is the reference standard for personal noise dosimetry. Critical requirements:

  • Microphone position: 5-10 cm from the ear (right or left, but CONSISTENT).
  • Windscreen mandatory for any outdoor measurement.
  • Minimum measurement duration: 3 hours OR full representation of all work activities.
  • At least 3 measurements on different days for a reliable LEX,8h statement.
  • Calibration BEFORE + AFTER measurement with ±0.5 dB tolerance.

The SL400 is designed so that all ISO 9612 requirements can be met, provided the operator follows the methodology.

Comparison with Alternatives

Extech SL400 (this unit): 1,135 EUR. Compact personal dosimeter with core functions.

3M Sound Detector SD-200: 1,500-2,000 EUR. Similar functionality, well-known brand name.

Casella dBadge2: 2,000-3,000 EUR. Professional Bluetooth dosimeter with app integration.

Bruel & Kjaer 4448/4448NF: 4,000-6,000 EUR. Reference class for calibration-verifiable measurements.

Larson Davis Spartan 730: 3,000-4,000 EUR. Very robust for harsh industrial environments.

Extech SL510 (stationary meter): ~500 EUR. NOT suitable for personal dosimetry, but suitable for spot assessment.

Legal Requirement: Why Dosimetry Is Mandatory

EU Directive 2003/10/EC and the German BGR 121 require employers to DOCUMENT their workers‘ daily noise exposure:

  • At LEX,8h ≥ 80 dB: written assessment required.
  • At LEX,8h ≥ 85 dB: hearing protection + medical examination + annual audiogram.
  • In case of proven hearing damage: recognition as an occupational disease, possible pension.

Without documented dosimetry, an employer cannot prove in a dispute that limit values were complied with. Personal dosimeters provide legally DEFENSIBLE documentation.

Cost savings: A single recognized occupational disease case due to hearing damage typically costs the employer 50,000-200,000 EUR over the remaining working life of the employee. A dosimeter for 1,135 EUR + a calibrator for 5,000 EUR + annual measurements are economically trivial by comparison.

Specifications

  • Model: Extech SL400.
  • Measurement range: 60-140 dB.
  • Frequency weighting: A, C, Z (selectable).
  • Time weighting: Slow, Fast, Impulse.
  • Peak detection: up to 143 dB.
  • Compliant with: OSHA, DOD, ACGIH, IEC 61252, ISO 9612.
  • Data logging: 999,999 measurement values.
  • Sampling rate: 1 sec. to 24 hrs. (configurable).
  • Microphone: 0.5″ (12.7 mm) electret condenser with windscreen.
  • Microphone cable: 80 cm, shielded.
  • Connection: USB.
  • Battery: 9V (included).
  • Compatible calibrator: 94 dB standard (sold separately).
  • Included in delivery: Belt clip, microphone with cable and windscreen, battery, USB cable, software, carrying case.

What You Get for Your Money

Extech SL400 personal noise dosimeter with belt clip and clip-on microphone (0.5″), 60-140 dB measurement range, A/C/Z frequency weighting, configurable time weighting and limit values, OSHA/IEC/ISO 9612 compliant, 999,999 data point memory, configurable sampling rate from 1 sec. to 24 hrs., USB interface with Windows software for report generation, complete with belt clip, microphone with windscreen, 9V battery and carrying case. 1,135 EUR.

A standard tool for HSE professionals, occupational physicians and safety officers in industry, construction, mining, aviation, the military, the music industry and other sectors with variable, mobile noise environments. The higher price compared with a stationary sound level meter is amply justified, because PERSONAL dosimetry is the only legally recognized method for determining the actual ear exposure of a mobile worker.

Read more: Extech SL400 Noise Dosimeter in the Shop →

More news