Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Why an Infrared Thermometer Gives Wrong Readings on Bare Metal When the Emissivity Cannot Be AdjustedWhy the Motor Trips on Startup Even Though the Running Current Is FineMeasuring Speed Without Touching the Machine: How a Stroboscope Makes Rotating Parts Appear to Stand StillWhy Humidity in the Warehouse Only Gets Noticed Once the Goods Are Already DamagedFinding Moisture Beneath the Surface Without Drilling a Single HoleChecking Antifreeze with Two Drops: How a Refractometer Reveals the Freezing Point of CoolantA Control Cabinet Terminal Gets Hot Before the Current Raises Any Alarm: Clamp Meter and Infrared Thermometer in One DevicePaint Coating Too Thin or Too Thick: Why Coating Thickness Only Becomes a Problem After ApplicationDetecting Moisture in Wood and Walls Before the Damage Becomes VisibleWhy the Cold Chain Usually Breaks at Night, and Only a Data Logger Shows ItVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Why an Infrared Thermometer Gives Wrong Readings on Bare Metal When the Emissivity Cannot Be AdjustedWhy the Motor Trips on Startup Even Though the Running Current Is FineMeasuring Speed Without Touching the Machine: How a Stroboscope Makes Rotating Parts Appear to Stand StillWhy Humidity in the Warehouse Only Gets Noticed Once the Goods Are Already DamagedFinding Moisture Beneath the Surface Without Drilling a Single HoleChecking Antifreeze with Two Drops: How a Refractometer Reveals the Freezing Point of CoolantA Control Cabinet Terminal Gets Hot Before the Current Raises Any Alarm: Clamp Meter and Infrared Thermometer in One DevicePaint Coating Too Thin or Too Thick: Why Coating Thickness Only Becomes a Problem After ApplicationDetecting Moisture in Wood and Walls Before the Damage Becomes VisibleWhy the Cold Chain Usually Breaks at Night, and Only a Data Logger Shows It

Why an Infrared Thermometer Gives Wrong Readings on Bare Metal When the Emissivity Cannot Be Adjusted

Published on November 25, 2026 at 12:59

A bearing is running hot, but the handheld thermometer shows only 60 °C, even though your hand on the housing tells you otherwise. Anyone who has ever measured bare aluminum, copper or polished steel with a simple infrared thermometer knows this situation. The device works, but the setting does not match the surface.

Dual-Laser-Infrarot-Thermometer

What the device is

The dual-laser infrared thermometer measures without contact from -50 to 1000 °C with a resolution of 0.1 °C. The optics have a ratio of 30:1. At a distance of 76.2 cm, the measuring spot is therefore around 2.5 cm in size. Two laser points converge at exactly this distance. If you keep to that distance, you can see on the target where the measuring spot lies. The response time is 0.15 seconds.

What problems it solves

Two sources of error most often distort infrared measurements: a measuring spot that is larger than the target, and an incorrect emissivity. A single laser point only marks the center of the measuring field. How large the field is remains a guess. The two converging points make the optimal distance visible. The emissivity can be set from 0.10 to 1.00. Painted, matte or organic surfaces are close to 0.95. Bare metals emit significantly less radiation. A rigidly fixed value reads too low on them.

When and why to use it

Whenever you cannot or do not want to touch the target: with rotating parts, live equipment, hot processes or parts that are difficult to access. The measuring range up to 1000 °C also covers furnaces, castings and heat treatment. For reliable values, the emissivity should match the material. It is often calibrated against a reference point, such as a piece of masking tape on the target.

Three practical applications

Workshop and maintenance: Motors, bearings and gearbox housings can be compared during operation. A bearing that is clearly warmer than its twin on the neighboring machine is spotted on a routine round before it fails.

Electrical systems and control cabinets: Terminals, fuses and contactors often heat up because of loose connections. From a safe distance, hot spots can be found without opening the cabinet. Thanks to the 30:1 optics, even a single terminal in a row can be measured.

Food production and building services: Incoming goods, refrigerated counters, baking ovens, pipes and heating circuits can be checked quickly. Comparing flow and return temperatures on plumbing and heating pipes takes seconds. Note that the device measures only the surface temperature, not the core temperature of a product.

The economic benefit

A measuring instrument of this kind saves time and prevents wrong decisions. An inspection round with a contact thermometer takes significantly longer and is impossible at hot or dangerous locations. An incorrectly measured temperature can lead to the unnecessary replacement of healthy parts or to damage being overlooked. A single avoided shutdown is enough to justify the purchase. And if you can adjust the emissivity, you no longer have to convert the values in your head.

The dual-laser infrared thermometer is a tool for anyone who wants to document surface temperatures regularly and traceably, even on difficult materials.

Learn more

More news